The refrigeration circuit is made up of four components.
Glycol chiller system diagram.
The ss glycol chiller 1 5 hp which will maintain lager temps and enable crash cooling for up to 3 vessels even in relatively high ambient temperatures.
The freezing point of a 60 40 ethylene glycol water mixture is much lower than that of either pure ethylene glycol or pure water.
Since each ftss kit includes its own dedicated t.
The compressor the condenser the expansion valve and the evaporator.
This is done by the power pack chilling and constantly.
A glycol cooling system is a type of long draw system that is commonly used in bars taverns and pubs.
These systems use a secondary refrigeration unit called a power pack or glycol chiller to maintain draft beer at the proper temperature all the way from the walk in cooler to the point of dispense.
We designed the chiller to integrate seamlessly with our ftss kits to provide a complete temperature control system.
This cool fluid removes heat from the process and the warm fluid returns to the chiller.
A refrigeration circuit and a fluid circuit.
Glycol cooled draft beer dispensing systems are typically used in commercial applications such as bars restaurants and stadiums.
What is a glycol chiller system.
In general a long draw system helps provide ice cold beer to places relatively far from where kegged beer is stored.
Industrial water or glycol chiller systems contain two main circuits.
The process water is the means by which heat transfers from the process to the chiller.
Glycol system technical product components in an effort to continually service you whether your the end user or a technician below is a list of the major components incoporated into your g d unit.
Glycol correction factors all heat exchangers experience a capacity loss when the fluid is a higher specific gravity than water glycols are heavy syrup like fluids at full concentration and become thinner when mixed with water.
For instance a solution of 10 ethylene glycol freezes at 3 4 c 25 9 f 30 ethylene glycol freezes at 13 7 c 7 3 f and 60 ethylene glycol freezes at 52 8 c 63 f.
Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol mixed with water to lower the freezing point in the application of the chilling system.
Too much glycol will therefore increase energy costs as the system works harder to accomplish the desired heating or cooling.
In most process cooling applications a pumping system circulates cool water or a water glycol solution from the chiller to the process.
Thus to achieve the same heat exchange inside the heat exchanger.
However the mixed solution of water glycol will be thicker heavier than the water alone was.
Since glycol has a lower specific heat than water higher concentrations of glycol in your closed loop water will reduce the heat carrying capacity of the system.
Here are the top three things you should know about glycol chillers.